Built for More: Uniform Coverage, Higher Yields, and Confident Variant Characterization.

Twist TrueAmp Library Preparation delivers consistent, high quality libraries for NGS target enrichment workflows, especially with challenging low input samples. Powered by Twist’s TrueAmp polymerase and optimized for enzymatic fragmentation, this workflow delivers high conversion efficiency, low GC bias, and balanced coverage, supporting accurate variant characterization across challenging genomic regions.

Reliable

Reliable Uniformity Across Challenging Genomic Regions

Improved coverage consistency reduces AT- and GC-related dropout, delivering better representation of difficult regions.

samples

High Conversion Efficiency From Low Input and Degraded Samples

High library yields across low input, FFPE, and variable quality samples help preserve precious material by reducing the need for reruns.

detection

High Fidelity Amplification for Confident Variant Detection

Twist TrueAmp polymerase minimizes amplification induced errors and bias, supporting accurate detection of low VAF variants.

Product data

TrueAmp Library Prep delivers higher pre-capture yield, consistent library sizes, and stronger mean target coverage from low input, degraded FFPE DNA, preserving library complexity and increasing reliable sequencing results from challenging samples.

Twist TrueAmp Library Prep delivers improved coverage uniformity and fewer zero coverage regions. Reduced target dropout increase confidence that critical regions are consistently sequenced.

The Twist TrueAmp Polymerase Mix delivers more uniform coverage across high- and low-GC regions, maintaining performance even with increased PCR cycling.

Twist TrueAmp Library Preparation Kits deliver consistent DNA library fragment sizes across a wide range of sample inputs, enabling mixed input workflows while maintaining uniform coverage and reproducible results at scale.

Twist TrueAmp Library Preparation Kit delivers repeatable DNA library fragment sizes across a broad range of input amounts supporting confidence in sequencing results and downstream analysis.

Video
Cdfa
Highconversion
cfdna
duplexing
Controlled Insert Sizes for Tunable Performance

High Yield and Coverage Where Samples Are Hardest

TrueAmp Library Prep delivers higher pre-capture yield, consistent library sizes, and stronger mean target coverage from low input, degraded FFPE DNA, preserving library complexity and increasing reliable sequencing results from challenging samples.

Cdfa

Figure 1 Performance comparison of enriched libraries with low-input FFPE degraded samples (DIN <2.2) between TrueAmp Library Preparation Kit and competitor K kit, demonstrating the optimal solution for challenging sample applications. (A) The Twist TrueAmp Library Preparation Kit generates superior pre-capture library yield, indicative of high library construction and amplification efficiency. (B) The Twist TrueAmp Library Preparation Kit shows higher library complexity when compared with the competitor’s kits. This allows for more unique DNA molecules that are sequenceable in the library, reducing sequencing costs. (C) Achieves higher coverage.

Uniform Coverage with Fewer Missed Targets

Twist TrueAmp Library Prep delivers improved coverage uniformity and fewer zero coverage regions. Reduced target dropout increase confidence that critical regions are consistently sequenced.

Highconversion

Figure 2. Performance comparison of enriched libraries with low-input FFPE degraded samples (DIN <2.2) between TrueAmp Library Preparation Kit and competitor K kit, demonstrating the optimal solution for challenging sample applications. (A) Delivers excellent coverage uniformity, measured by a lower fold-80 base penalty. (B) Reduced regions with no coverage, measured by Percentage of Zero Coverage Targets.

Improved Coverage Across GC Extremes

The Twist TrueAmp Polymerase Mix delivers more uniform coverage across high- and low-GC regions, maintaining performance even with increased PCR cycling.

cfdna

Figure 3. Normalized GC bias trace showing improved coverage of the Twist TrueAmp polymerase. Libraries were prepared with Twist TrueAmp Library Preparation Kit and amplified with different polymerases and cycles. Upper panel: Normalized coverage against GC window plots comparing polymerases at 3 cycles of PCR. Lower panel: Normalized coverage against GC window plots comparing polymerases at 16 cycles of PCR.

Built for Consistency Across Inputs and Workflows

Twist TrueAmp Library Preparation Kits deliver consistent DNA library fragment sizes across a wide range of sample inputs, enabling mixed input workflows while maintaining uniform coverage and reproducible results at scale.

duplexing

Figure 4. Reliable library size with Twist TrueAmp Library Prep Kit, even from ultra-low inputs. 500 ng, 100 ng, 50 ng, 10 ng and 1 ng (gDNA) were fragmented at 32°C. 3, 5, 6, 8, 10, and 14 cycles of PCR were utilized for amplification, respectively. Samples have been performed in duplicates. A: Electropherograms of NGS libraries generated with the Twist TrueAmp Library Preparation Kit. B: Concentration of libraries after amplification for various DNA inputs.

Controlled Insert Sizes for Tunable Performance

Twist TrueAmp Library Preparation Kit delivers repeatable DNA library fragment sizes across a broad range of input amounts supporting confidence in sequencing results and downstream analysis.

Controlled Insert Sizes for Tunable Performance

Figure 5. Tunability of Twist TrueAmp Library Prep Kit. A: Five electropherograms of NGS libraries generated using differing fragmentation times. 50 ng of high-quality gDNA was fragmented for various times at 32°C. 6 cycles of PCR were utilized for amplification. B: Median insert size vs time. 50 ng of high-quality gDNA was fragmented for various times at 32°C. Amplification was performed using 6 cycles of PCR. Samples were captured using the Twist Exome 2.0 panel.

1 / 5
Cdfa

High Yield and Coverage Where Samples Are Hardest

TrueAmp Library Prep delivers higher pre-capture yield, consistent library sizes, and stronger mean target coverage from low input, degraded FFPE DNA, preserving library complexity and increasing reliable sequencing results from challenging samples.

Highconversion

Uniform Coverage with Fewer Missed Targets

Twist TrueAmp Library Prep delivers improved coverage uniformity and fewer zero coverage regions. Reduced target dropout increase confidence that critical regions are consistently sequenced.

cfdna

Improved Coverage Across GC Extremes

The Twist TrueAmp Polymerase Mix delivers more uniform coverage across high- and low-GC regions, maintaining performance even with increased PCR cycling.

duplexing

Built for Consistency Across Inputs and Workflows

Twist TrueAmp Library Preparation Kits deliver consistent DNA library fragment sizes across a wide range of sample inputs, enabling mixed input workflows while maintaining uniform coverage and reproducible results at scale.

Controlled Insert Sizes for Tunable Performance

Controlled Insert Sizes for Tunable Performance

Twist TrueAmp Library Preparation Kit delivers repeatable DNA library fragment sizes across a broad range of input amounts supporting confidence in sequencing results and downstream analysis.