OVERVIEW DATA ORDERING & SPECS RESOURCES
OVERVIEW

Twist’s Universal Adapter Systems improve the performance of any ‘T-A’ overhang ligation library preparation workflow for next-generation sequencing (NGS) applications. Engineered to optimize the performance of Twist’s Library Preparation and Target Enrichment products, the systems consist of Twist’s Universal Adapters and either Twist Unique Dual-Indexed (UDI) Primers or Twist HT UDI Primers. 

Twist Universal Adapters

The proprietary design of the universal TruSeq-compatible adapters ensures compatibility with all ‘T-A’ overhang workflows and eliminates formation of undesired adapter dimer. It also contributes to increasing the workflow’s overall yield, which is especially beneficial prior to a target enrichment step. 

Twist 10 bp Unique Dual-Indexed (UDI) Primers

Twist’s UDI primers contain mixed primer pairs, which enable higher confidence sample pooling than combinatorial approaches. The index design allows for correction of substitutions, insertions, and deletions within the index reads during post-sequencing processing.

Twist 12bp High Throughput (HT) UDI Primers

Available in automation-friendly 96-well or 384-well plate formats, Twist’s HT UDI primers offer the most scalable solution for high throughput sequencing. All 3,072 unique indexes take into consideration base and color channel balancing, making them optimal for either two-color or four-color chemistries. 

Maximize Performance
Maximize Performance
Drastically reduce adapter dimer formation
Use fewer PCR cycles during library preparation to reduce errors and bias introduced during amplification
Increase Flexibility
Increase Flexibility
Can be used with all ‘T-A’ overhang ligation systems
Compatible with all Illumina sequencing chemistries (2- or 4-color) and flow cell types (non-patterned and patterned)
Boost Efficiency
Boost Efficiency
Scale your multiplexing with up to 3,072 available indexes
Ready-to-use formulation
Reduces per-sample sequencing cost
No More Sample Mix Up

Looking for a streamlined method to detect sample mix-ups?
See how the Twist Human Sample ID kit integrates with Twist’s Universal Adapter Systems.

Learn More

Twist’s Universal Adapter Systems improve the performance of any ‘T-A’ overhang ligation library preparation workflow for next-generation sequencing (NGS) applications. Engineered to optimize the performance of Twist’s Library Preparation and Target Enrichment products, the systems consist of Twist’s Universal Adapters and either Twist Unique Dual-Indexed (UDI) Primers or Twist HT UDI Primers. 

Twist Universal Adapters

The proprietary design of the universal TruSeq-compatible adapters ensures compatibility with all ‘T-A’ overhang workflows and eliminates formation of undesired adapter dimer. It also contributes to increasing the workflow’s overall yield, which is especially beneficial prior to a target enrichment step. 

Twist 10 bp Unique Dual-Indexed (UDI) Primers

Twist’s UDI primers contain mixed primer pairs, which enable higher confidence sample pooling than combinatorial approaches. The index design allows for correction of substitutions, insertions, and deletions within the index reads during post-sequencing processing.

Twist 12bp High Throughput (HT) UDI Primers

Available in automation-friendly 96-well or 384-well plate formats, Twist’s HT UDI primers offer the most scalable solution for high throughput sequencing. All 3,072 unique indexes take into consideration base and color channel balancing, making them optimal for either two-color or four-color chemistries. 

No More Sample Mix Up

Looking for a streamlined method to detect sample mix-ups?
See how the Twist Human Sample ID kit integrates with Twist’s Universal Adapter Systems.

Learn More

Maximize Performance
Maximize Performance
Drastically reduce adapter dimer formation
Use fewer PCR cycles during library preparation to reduce errors and bias introduced during amplification
Increase Flexibility
Increase Flexibility
Can be used with all ‘T-A’ overhang ligation systems
Compatible with all Illumina sequencing chemistries (2- or 4-color) and flow cell types (non-patterned and patterned)
Boost Efficiency
Boost Efficiency
Scale your multiplexing with up to 3,072 available indexes
Ready-to-use formulation
Reduces per-sample sequencing cost
DATA
Increase Final Yields During Library Preparation

Twist Universal Adapters and HT Universal Adapters return higher total yields with fewer PCR cycles. This ultimately leads to the production of more library with fewer PCR errors to drive improvements in target enrichment efficiency.”

The chart to the right shows how using Twist Universal Adapters for insert ligation and UDI primer PCR amplification generates a robust library.

 

 NGS Reagents and Kits Universal Adapters Workflow
Reduce Adapter Dimer Formation for Robust Library Construction

Library preparation and target enrichment work together to influence the ability to call variants in sequencing. Consistently constructing robust libraries is important for successful hybrid capture. When adapters dimerize during library preparation, they generate undesired products and reduce the effective concentration of adapters available for ligation to inserts. Using Twist Universal Adapters and Primers during library construction minimizes this problem.

Twist Universal Adapters minimize adapter dimer formation during library preparation.

 

 

 NGS Reagents and Kits Universal Adapters Fluorescent Units Graph
Increase Final Yields During Library Preparation

Twist Universal Adapters and HT Universal Adapters return higher total yields with fewer PCR cycles. This ultimately leads to the production of more library with fewer PCR errors to drive improvements in target enrichment efficiency.”

The chart to the right shows how using Twist Universal Adapters for insert ligation and UDI primer PCR amplification generates a robust library.

 

 NGS Reagents and Kits Universal Adapters Workflow
Reduce Adapter Dimer Formation for Robust Library Construction

Library preparation and target enrichment work together to influence the ability to call variants in sequencing. Consistently constructing robust libraries is important for successful hybrid capture. When adapters dimerize during library preparation, they generate undesired products and reduce the effective concentration of adapters available for ligation to inserts. Using Twist Universal Adapters and Primers during library construction minimizes this problem.

Twist Universal Adapters minimize adapter dimer formation during library preparation.

 

 

 NGS Reagents and Kits Universal Adapters Fluorescent Units Graph
ORDERING & SPECS
Universal Adapter System Product SKUs

101307

Twist Universal Adapter System TruSeq Compatible, 16 Samples

101308

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate A

101309

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate B

101310

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate C

101311

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate D
HT Universal Adapter System Product SKUs

106390

Twist HT Universal Adapter System TruSeq Comp, 96W AAA01-04

106391

Twist HT Universal Adapter System TruSeq Comp, 96W AAA05-08

106392

Twist HT Universal Adapter System TruSeq Comp, 96W AAA09-12

106393

Twist HT Universal Adapter System TruSeq Comp, 96W AAA13-16

106396

Twist HT Universal Adapter System TruSeq Comp, 96W BBB01-04 (Coming soon!)

106398

Twist HT Universal Adapter System TruSeq Comp, 96W BBB05-08 (Coming soon!)

106399

Twist HT Universal Adapter System TruSeq Comp, 96W BBB09-12 (Coming soon!)

106400

Twist HT Universal Adapter System TruSeq Comp, 96W BBB13-16 (Coming soon!)

106401

Twist HT Universal Adapter System TruSeq Comp, 384W AAA01

106402

Twist HT Universal Adapter System TruSeq Comp, 384W AAA02

106403

Twist HT Universal Adapter System TruSeq Comp, 384W AAA03

106404

Twist HT Universal Adapter System TruSeq Comp, 384W AAA04

106405

Twist HT Universal Adapter System TruSeq Comp, 384W BBB01 (Coming soon!)

106406

Twist HT Universal Adapter System TruSeq Comp, 384W BBB02 (Coming soon!)

106407

Twist HT Universal Adapter System TruSeq Comp, 384W BBB03 (Coming soon!)

106408

Twist HT Universal Adapter System TruSeq Comp, 384W BBB04 (Coming soon!)

The Twist Universal Adapter System is for research use only, and subject to additional use restrictions as set forth in Twist’s Supply Terms and Conditions.

Universal Adapter System Product SKUs

101307

Twist Universal Adapter System TruSeq Compatible, 16 Samples

101308

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate A

101309

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate B

101310

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate C

101311

Twist Universal Adapter System TruSeq Compatible, 96 Samples Plate D
HT Universal Adapter System Product SKUs

106390

Twist HT Universal Adapter System TruSeq Comp, 96W AAA01-04

106391

Twist HT Universal Adapter System TruSeq Comp, 96W AAA05-08

106392

Twist HT Universal Adapter System TruSeq Comp, 96W AAA09-12

106393

Twist HT Universal Adapter System TruSeq Comp, 96W AAA13-16

106396

Twist HT Universal Adapter System TruSeq Comp, 96W BBB01-04 (Coming soon!)

106398

Twist HT Universal Adapter System TruSeq Comp, 96W BBB05-08 (Coming soon!)

106399

Twist HT Universal Adapter System TruSeq Comp, 96W BBB09-12 (Coming soon!)

106400

Twist HT Universal Adapter System TruSeq Comp, 96W BBB13-16 (Coming soon!)

106401

Twist HT Universal Adapter System TruSeq Comp, 384W AAA01

106402

Twist HT Universal Adapter System TruSeq Comp, 384W AAA02

106403

Twist HT Universal Adapter System TruSeq Comp, 384W AAA03

106404

Twist HT Universal Adapter System TruSeq Comp, 384W AAA04

106405

Twist HT Universal Adapter System TruSeq Comp, 384W BBB01 (Coming soon!)

106406

Twist HT Universal Adapter System TruSeq Comp, 384W BBB02 (Coming soon!)

106407

Twist HT Universal Adapter System TruSeq Comp, 384W BBB03 (Coming soon!)

106408

Twist HT Universal Adapter System TruSeq Comp, 384W BBB04 (Coming soon!)

The Twist Universal Adapter System is for research use only, and subject to additional use restrictions as set forth in Twist’s Supply Terms and Conditions.

RESOURCES
Increase multiplexing and library yield
Increase multiplexing and library yield
Increase multiplexing and library yield